Caustic Storage Tank - Fiberglass Tanks
Caustic Storage Tank
FTPI 2007-1 recommends that an integrity tank inspection be performed by a certified tank inspector every 20 years for tanks/vessels in Hazardous Substance service.

The subject photographs were taken during an internal inspection of a 20 year old 20,000 gallon 30% sodium carbonate aqueous solution tank located in Texas that was weeping the solution from the bottom knuckle. An internal inspection showed Barcol hardness deterioration and crazing of the interior resin corrosion barrier. The first photograph is of the interior shell wall using a 7 pixel resolution camera. The photograph shows resin crazing and where a piece of resin was removed with a blunt instrument. The second photograph is of the exterior shell wall above the bottom knuckle. The photograph shows the exterior resin coat has deteriorated and exposed glass fibers. The resin and glass fiber matrix could be scraped away with a blunt instrument and the tank was replaced before catastrophic failure could occur.

If you have any questions or would like more information, please email us, or use our online request form.